Health Information Health Information Health Information
Health Information
Bookmark !     pulse oximeter oxygen saturation  Bookmark Health Information   pulse oximeter oxygen saturation  Make Health Information Homepage       
Health Information

Health Information Health Information Health Information
Health Encyclopedia Health Information
Health Information Health Information Health Information
Health InformationHealth InformationHealth Information
Health Information

Liposuction & Lipoplasty & Cosmetic Surgery


Liposuction & Lipoplasty & Cosmetic Surgery As a Health Information Encyclopedia, We say that Liposuction, also known as lipoplasty or suction-assisted lipectomy, is cosmetic surgery performed to remove unwanted deposits of fat from under the skin. The surgeon sculpts and re-contours a body by removing excess fat deposits that is resistant to reduction by diet or exercise. The loss of fat cells is permanent. Smoother, pleasing body contours without excessive bulges
Health Information
Health Encyclopedia Health Information Health Information
Health Encyclopedia Health Encyclopedia Health Encyclopedia
Health Information

Hair Loss Treatment & Hair Transplantation


Health Information Hair transplantation is a surgical procedure used to treat baldness, hair loss (alopecia). Tiny patches of scalp are removed from the back and sides of the head; implanted in the bald spots in front and top of head. Hair transplantation is a cosmetic procedure in hair loss treatment performed on men and occasionally on women who have significant hair loss, thinning hair, or bald spots where hair no longer grows.
Health Information
Health Information Health Encyclopedia Health Information
 

PULSE OXIMETER OXYGEN SATURATION

Internal Medicine
The pulse oximeter is a photoelectric instrument for measuring oxygen saturation of blood. A pulse oximeter measures the amount of oxygen present in blood by registering pulsations within an arteriolar bed (an area between arteries and capillaries). It is a noninvasive method widely used in hospitals on newborns, persons with pulmonary disorders, and individuals undergoing pulmonary and cardiac procedures. Oxygen levels can be estimated during exercise, surgery, or other medical procedures, or while a person is asleep.

The oximeter consists of a light-emitting diode (LED), a photodetector probe containing a permanent or disposable sensor, alarms for pulse rate and oxygen levels, a display screen, and cables. The device works by Hosemitting beams of red and infrared light that are passed through a pulsating arteriolar bed. Sensors detect the amount of light absorbed by oxyhemoglobin and deoxyhemoglobin in the red blood cells. The ratio of red to infrared light measured by the photodetector indicates the amount of oxygen present in the blood.

The sensor is attached to the body over the arteriolar area in the ear, the fingertip, the big toe, or across the bridge of the nose. Clip sensors can be used on fingers or the earlobe. The pulse oximeter is widely used in most hospitals and in research laboratories that study pulmonary function. Oximeters are used in hospital settings such as intensive care units, pulmonary units, and in health care centers. Portable hand-held devices are available, and are used to spot check patients and for in-home use under the supervision of a physician.

Usage
Several steps can be taken to enhance accurate readings. If possible, the patient should not smoke 24 hours prior to pulse oximetry. Fingernail polish should be removed if the oximeter will be attached to the finger. For people with poor circulation, hands should be slowly warmed with warm towels before attaching the oximeter.

Abnormally high or low temperatures, as well as reduced hemoglobin, can influence the amount of oxygen adhering to the hemoglobin within the red blood cells, altering the reading. The sensor should be wrapped securely around the finger to prevent outside light from interfering with the reading, which could render it invalid. The device must not be used near flammable anesthetics.

Hit: 740 times
pulse oximeter oxygen saturation  Print Health Information   pulse oximeter oxygen saturation  Send to a Friend

Related Health Information in Internal Medicine :

The Most Popular Health Information Articles
Abdominoplasty Tummy Tucka Costs | Hair Loss Treatment Hair Transplantation | Liposuction Lipoplasty Cosmetic Surgery | Laser Eye Surgery Iridotomy | Prostate Cancer Treatment | Rhinoplasty Nose Molding | Plastic Reconstructive Cosmetic Surgery | Private Health Insurance Plans | Lasik Eye Surgery | Gastric Bypass Surgery | Laser Surgery | Snoring Surgery | Smoking Cessation | Lung Cancer Treatment Lobectomy | Sclerotherapy For Varicose Veins | Smoking Cessation 2 | Septoplasty Operation Surgery | Impotence Treatment | Urinary Incontinence Injection Treatment | Abdominoplasty Risks Aesthetic Results | Long Term Health Care Insurance | Laser Eye Treatment Iridotomy | Sclerotherapy For Esophageal Varices | Proton Pump Inhibitors Adverse Reactions | Medical Abortions Costs Information | Knee Replacement | Liver Ultrasound Normal Appearance | Anorexia Nervosa Child Health Care | Anorectal Malformations Baby Health | Lower Gastrointestinal Bleeding In Children | Ambiguous Genitalia Children Babies | X-Ray For Children |

pulse oximeter oxygen saturation
pulse oximeter oxygen saturation pulse oximeter oxygen saturation Health Information